High Accuracy Versatile Electromagnetic Flow Sensor Mag Flow Transmitter For Strong Acids DN80

Basic Properties
Place of Origin: Jiangsu, China
Brand Name: INSTE
Model Number: ISTLDG
Trading Properties
Minimum Order Quantity: 1 set
Price: USD200-800/ set
Payment Terms: T/T, Western Union
Supply Ability: 100 sets per day
Product Summary
High-accuracy DN80 electromagnetic flow sensor for strong acids. ±0.5% accuracy, handles -20°C~120°C fluids, multiple power options, and RS485/HART communication. SS316L/Hastelloy electrodes with DIN/ANSI/JIS flanges.

Product Details

Highlight:

High Accuracy Electromagnetic Flow Sensor

,

Acid Proof Flow Meter

,

DN80 Magnetic Flow Transmitter

Caliber: DN80mm
Power Supply: AC220V,DC24V, 3.6V
Display: Instantaneous Flow, Total Flow, Flow Velocity
Structure Type: Integrate Or Remote
Pressure: 0.6Mpa-10Mpa
Accuracy: ±0.5% Of Reading
Fluid Temperature: -20°C~120°C
Ambient Temperature: -20℃~60℃
Environment Temperature: -10℃~+60℃
Output: 4-20mA
Communication: RS485 MODBUS RTU, HART, GPRS
Electrode: SS316L, Hastelloy B, Hastelloy C, Titannium, Tantanlum, Platinum-iridium
Flange Standard: DIN, ANSI, JIS
Product Description
High Accuracy Versatile Electromagnetic Flow Sensor Mag Flow Transmitter For Strong Acids DN80
This high-accuracy electromagnetic flow sensor and transmitter is specifically designed for measuring strong acids with DN80 pipe size, offering versatile installation options and reliable performance.
Instrument Installation Guidelines
Proper installation is critical for accurate measurement, optimal performance, and extended service life of the electromagnetic flowmeter.
Installation Site Selection
  • Avoid locations near magnetic objects and strong electromagnetic equipment (large motors, transformers) to prevent interference with sensor magnetic fields and flow signals
  • Install in dry, ventilated areas - avoid damp or flood-prone locations
  • Protect from direct sun and rain exposure; maintain environment below 60°C and under 95% relative humidity
  • Choose easily accessible locations for maintenance and service
  • Install on the discharge side of pumps, not the suction side; position valves downstream of the flowmeter
Installation Requirements
  • Sensor can be installed in straight pipes, horizontal pipes, or tilted pipes with electrodes positioned horizontally
  • Ensure full pipe flow at installation point to prevent air pockets on electrodes
  • For liquid-solid two-phase flow, vertical installation is recommended for even liner wear and extended service life
  • If partial flow conditions exist, elevate downstream piping to maintain full pipe flow - avoid installation at pipeline peaks or outlets
  • For non-standard velocity conditions, use reducer cones or modified pipe sections matching sensor diameter with straight pipe requirements: upstream ≥10 DN, downstream ≥5 DN
  • Maintain straight pipe sections: upstream ≥10 DN, downstream ≥5 DN (where DN is pipe diameter)
Instrument Connection
  • For remote signal connection, use only customized special cables - shorter lengths preferred
  • Excitation cables should use YZ medium rubber cable matching signal cable length
  • Signal cables must be separated from power cables and not run in the same conduit
  • Keep signal and excitation cables as short as possible; cut excess length rather than coiling
  • At sensor interface, form cable into U-shape to prevent water ingress
High Accuracy Versatile Electromagnetic Flow Sensor Mag Flow Transmitter For Strong Acids DN80 0